Nitrous Controller & Data Logger
The NC-1 and NC-2 units have identical features and capabilities except that the NC-2 can directly drive two nitrous stages with progressive control (modulated flow). The NC-1 requires external relays and is limited to on/off control.
Features:
- Drives two nitrous stages and purge solenoid. NC-2 is capable of 40 amp output on each stage
- Each stage is independently programmable based on throttle position, RPM, vehicle speed, time delay, and first gear lockout. NC-2 adds capability for RPM or time based progressive control
- Output for purge solenoid (requires external relay). Programmable automatic purge when system is armed
- Flexible RPM input compatible with high voltage coil drive (vehicles with coil packs or distributor ignition), standard 12 volt tach signal, or low level logic drive (newer vehicles with coil-on-plug)
- General purpose input/output (GPIO) terminal. Programmable for use as shift light output, additional stage enable input, or control output for ignition retard
- Status LED output (ideal for use with arming switch containing LED)
- Built-in data logging. Ideal as basic vehicle data logger during dyno tuning or drag racing. Logs data whenever system is armed. Stores last 5 minutes of data at 10 samples/second
- Data logged includes throttle position, RPM, vehicle speed, status of all inputs and outputs, and two 0-5 volt analog inputs
- 0-5 Volt analog inputs are compatible with Daytona Sensors single or dual channel WEGO II systems for logging wide-band air/fuel ratio data
- Heavy duty industrial grade clamping terminal blocks allow easy and reliable hookup without soldering or crimping
- Compact size: NC-1 is 3.3”L x 2.4”W x 1.1”H and NC-2 is 4.1”L x 2.8”W x 1.1”H (not including mounting feet and terminal block)
- USB interface to laptop PC. Powerful Windows software for programming controller and downloading logged data
PC Link Nitrous Parameters
PC Link Progressive Control
PC Link RPM Based Progressive Control
Nitrous Log Real Time Display
Nitrous Log Chart Display
PC Link Nitrous Software
PC Link software runs under Microsoft Windows 98/ME/XP/Vista. PC Link allows the user to program all the parameters and tables within the nitrous controller. Minimum PC requirement is a 300 MHz Pentium with super VGA display (SVGA with 1024 x 768 pixel resolution). The nitrous controller connects to the PC by means of al USB interface. A USB cable is supplied with the unit. The PC must have a free USB port.
- Used to establish controller scale factors, general setup parameters, and independent control parameters for each nitrous stage.
- Program control strategy based on throttle position, RPM and vehicle speed windows, time delay, and first gear lockout
- RPM or time based progressive control (NC-2 only). Easy graphic editing of ramp with 32 points spaced at 250 RPM or 0.25 second intervals
- Use of RPM and vehicle speed inputs is optional. Control strategy can be as simple as a time delay or time based progressive ramp initiated by a wide open throttle switch
- You can download and upload to the module, open and save files to disk, and print setup values including graphs for progressive ramps. Includes comprehensive on-line help system
PC Link software is free! You can always download the latest version of the software and instruction sheet from website. The software will run in demo mode without a nitrous controller attached. For your convenience, we include a copy on CDROM when you purchase the NC-1 or NC-2 system.
Download PC LInk Software
Nitrous Log Software
Both the NC-1 and NC-2 feature comprehensive data logging capability. During initial system checkout and dyno testing, you can display real time engine data on an instrument panel type screen. The nitrous controller also stores data for the last 4-1/2 minutes of operation (system armed). You can download and display this data on a chart recorder type screen. Data is available for all inputs and output functions. The Nitrous Log software has the same PC requirements as described above for the PC Link software. For more detailed information, we suggest that you download the Nitrous Log software and instructions. The software download includes a sample file with actual data.
- Two modes: real time display and chart display of data downloaded from the module
- Real time display of system and engine data on an instrument panel layout with round tach and speedometer gauges and bar graph gauges for most other parameters. Used for initial system setup and to monitor operation during dyno tuning
- Chart display for downloaded data allows you to monitor vehicle operation on the track. You have a range of capabilities for analyzing the displayed data. This feature is especially useful for checking system operation during a “dry run” before the nitrous is turned on.
- You can download data from the module, open and save files to disk, and print chart graphics. Includes comprehensive on-line help system
Nitrous Log software is free! You can always download the latest version of the software and instruction sheet from the website. The software will run in demo mode without a nitrous controller attached. For your convenience, we include a copy on CDROM when you purchase the NC-1 or NC-2 system.
Download Nitrous Log Software
Part Number |
Description | Racer Price | |
---|---|---|---|
64-NC-2 |
Daytona Progressive Controller - Datalogger NC-2 |
$363.75 |
|
64-NC-1 |
Daytona NC-1 |
$254.75 |